Free Userbar - Userbars - User Bar - User Bars
 
Advanced search
Registered users

Username:

Password:

Log me on automatically next visit?

¬ Forgot password
¬ Registration

» Upload Userbar
» Animate Userbar
» Userbars Tutorial
» Userbar Tournaments
» Forum
» Chat Room
» FAQ
» Links

• PC Cheat Codes

>> If you dont know how to design a userbar, then write here a Userbar that you want. >> If you know how to design them help these people and design what they request.




USERBARS.org | Free Forum Userbars

On eBay now
eBay

AVR EA05A Automatic Voltage Regulator Control Panel Generator Controller

AVR EA05A Automatic Voltage Regulator Control Panel Generator Controller
$30.22

Buy Now

Description:Sensing InpuuutVoltage 220 / 380 / 440 VAC, 1 phase2 wireDIP switch selectableFrequency 50 / 60 Hz, DIP switch selectablePower InputVoltage 100 ~ 300 VAC, 1 phase 2 wireOutputVoltage Max. 90 VDC @ 240 VAC inputCurrent Continuous 5AIntermittent 7A for 10 secResistance Min. 15 ohm Max. 100 ohmVoltage Regulation< ± 0.5% ( with 4% engine governing )Voltage Build-upResidual voltage at AVR terminal > 5 VACThermal Drift0.03% per °C change in AVR ambientExternal Volts Adjustmen± 7% with 1K ohm 1 watt trimmerEMI SuppressionInternal electromagnetic interference filteringUnit Power DissipationMax. 8 wattUnder Frequency Protection (Factory Setting)60 Hz system presets knee point at 55 Hz50 Hz system presets knee point at 45 HzSoft Sta...

AVR EA05A Automatic Voltage Regulator Control Panel Generator Controller

Description:
Sensing Inpuuut
Voltage 220 / 380 / 440 VAC, 1 phase2 wire
DIP switch selectable
Frequency 50 / 60 Hz, DIP switch selectable
Power Input
Voltage 100 ~ 300 VAC, 1 phase 2 wire
Output
Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 5A
Intermittent 7A for 10 sec
Resistance Min. 15 ohm Max. 100 ohm
Voltage Regulation
< ± 0.5% ( with 4% engine governing )
Voltage Build-up
Residual voltage at AVR terminal > 5 VAC
Thermal Drift
0.03% per °C change in AVR ambient
External Volts Adjustmen
± 7% with 1K ohm 1 watt trimmer
EMI Suppression
Internal electromagnetic interference filtering
Unit Power Dissipation
Max. 8 watt
Under Frequency Protection (Factory Setting)
60 Hz system presets knee point at 55 Hz
50 Hz system presets knee point at 45 Hz
Soft Start Ramp Time
3 sec.
Dimensions
101mm L * 69mm W * 47.5mm H
Weight
183g ± 2%
2. Wiring
When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together. or connect independent.(as show as figure2).
2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
C above 600V.
The EXT.VR connection wires must be made of isolated wiring.
3. Adjustments
The voltage setting for 220V/380V/440V and the
frequency setting for 50/60HZ is show in figure7.
Please check the voltage/frequency selector setting
is correct before start the generator.

Caution:
The Generator Or Avr May Be Damaged
If The Voltage / Frequency Selector
Setting Is Incorrect.
Ufro Dip:
1. Before you turn on the generator, please turn the
voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
2. Adjust “Stability Adjustment” clockwise slowly to
change the response time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
4. Field Flashing
When the regulator is operated with the generator for
the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
1. With the Prime-mover at rest and the regulator’s
field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
2. Allow approximately 3 seconds before removing
the DC source.
3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
4. If repeating steps a. and b. does not result in
generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

Package Including:
1 × Automatic Voltage Regulator Controller AVR EA05A Genset Parts
1×Product Instructions


Item SpecificsCountry of Origin United StatesBrand Tool libraryMPN EA05AType Automatic Voltage RegulatorQuantity 1 PCModel EA05AEquipment Type Voltage RegulatorWarranty 1 Year
Payment

Once payment is cleared, we will arrange for shipment as soon as possible to ensure your item arrives on time

Shipping

1.Usually your Items will be shipped within 1-3 business day after your payment is cleared.
International orders may take 10 to 30 business days to arrive.
2.We have CA, NJ warehouses and ship items may vary according to the stock.
3.No shipping on Weekends or US Public Holidays.

Returns

We now offer for US buyers 30 days money back guarantee . If US buyers does not like the item or feels not satisfied with the product, we will cover the return shipping fee & US buyer can return the item and get refund for item price only.

Contact Us

If there are any defects or issues with the product, we will resolve them for you as soon as possible. Thank you for your understanding and support.

response

We offer high quality products, competitive prices and prompt delivery .Please add us to your list of favorite sellers. Our company has experience in serving the global aftermarket. Thank you for your business. Best wishes!

CNCHeavy Machinery PartsHand ToolsElectric Motor & PumpOutdoor Garden Shop CategoryStore Home Business & Industrial▷CNC♢Edge finder♢Drill Bits♢Spring Collet♢Boring Bar♢Collet Chuck♢Blade♢Pull Stud♢Quick Change Tool Post♢Drill Chuck♢Drill Chuck Arbors♢Live center♢Vise♢Milling Tools♢Rivet Gun♢Wrenches♢Hydraulic Crimper♢Casters♢Outside Micrometer♢Balance Level♢Drill Bits♢Other▷Metalworking Supplies♢Sanding Disc♢Metal Cut Off Wheels♢Flap Discs♢Welding Wire♢Cable♢Piston Driver♢Other▷Generator Accessories♢Automatic Voltage Regulator♢Generator Carburetor♢Other▷Industrial Control Module♢Control Valves♢Roller Chain♢Pressure Washer Pump♢Electric Door Fittings♢Decoration Materials♢Paint Sprayers♢Other◈New Products Discount Zone Home & Garden▷Lawn Mowers♢Carburetor♢Repair Kits♢Transmission System♢Ignition Coil♢Mower Spindle♢Mower Starter♢Lawn Mower Seat♢Lubrication System♢Recoil Starter♢Solenoid♢Air Filter♢Other▷Leaf Blower♢Leaf Blower Accessories▷Snow Blower♢Snow Blower Accessories▷Garden Tool♢Courtyard Garden Facilities♢Water Pipe♢Grass Repellent Cloth♢Braided Rope♢Nursery Cup♢Extension ladder♢Gallon Basin▷Outdoor Sports♢Sports Equipment♢Swimming pool supplies▷Other Tool♢Other Tool Accessories Commercial Machinery▷Construction Machinery♢Excavator Parts♢Truck Parts▷Forestry Equipment♢Tractor Parts♢Other OtherHot Item 5Inch Bench Vise with Anvil Swivel Locking Base Table Top Clamp Heavy Duty Vice USD 46.69 Double shoulder Strap For Echo Universal Trimmer Harness Brush Cutter Orange USD 10.17 48 Pack Oscillating Multi Tool Saw Blades 24 Pcs 1-3/8 Inch & 24 Pcs 1-3/4 Inch USD 17.06 E6013 1/8\" x 14\" Premium Arc Welding Rods Carbon Steel Electrode 10 lbs with Box USD 24.07 2Pcs For John Deere Riding Mowers Replacement 15 x 6.00-6\" Tires Assembly 464881 USD 54.11 New List Item For Swimming Pools and Pond For Hayward CL220 Off-line Automatic Chemical Feeder USD 43.02 High Quality 2 Gallon Pump Sprayer Stainless Steel Sprayer With Reinforced Hose USD 59.52 3 Pack Arch Backdrop Stand (7.2/6.6/6FT) Balloon Arch Metal Stand W/ Cloth Cover USD 70.03 2 Gallon 8L Stainless Steel Sprayer Farm Garden Hand Pump Sprayer With Nozzles USD 59.52 20pk 220971 Plasma Cutting Electrode for PMX125 Plasma Cutting Torch Consumable USD 52.70 Help & InfoPayment PolicyShipping PolicyReturn PolicyFAQAbout Us AVR EA05A Automatic Voltage Regulator Control Panel Generator Controller

Description:
Sensing Inpuuut
Voltage 220 / 380 / 440 VAC, 1 phase2 wire
DIP switch selectable
Frequency 50 / 60 Hz, DIP switch selectable
Power Input
Voltage 100 ~ 300 VAC, 1 phase 2 wire
Output
Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 5A
Intermittent 7A for 10 sec
Resistance Min. 15 ohm Max. 100 ohm
Voltage Regulation
< ± 0.5% ( with 4% engine governing )
Voltage Build-up
Residual voltage at AVR terminal > 5 VAC
Thermal Drift
0.03% per °C change in AVR ambient
External Volts Adjustmen
± 7% with 1K ohm 1 watt trimmer
EMI Suppression
Internal electromagnetic interference filtering
Unit Power Dissipation
Max. 8 watt
Under Frequency Protection (Factory Setting)
60 Hz system presets knee point at 55 Hz
50 Hz system presets knee point at 45 Hz
Soft Start Ramp Time
3 sec.
Dimensions
101mm L * 69mm W * 47.5mm H
Weight
183g ± 2%
2. Wiring
When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together. or connect independent.(as show as figure2).
2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
C above 600V.
The EXT.VR connection wires must be made of isolated wiring.
3. Adjustments
The voltage setting for 220V/380V/440V and the
frequency setting for 50/60HZ is show in figure7.
Please check the voltage/frequency selector setting
is correct before start the generator.

Caution:
The Generator Or Avr May Be Damaged
If The Voltage / Frequency Selector
Setting Is Incorrect.
Ufro Dip:
1. Before you turn on the generator, please turn the
voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
2. Adjust “Stability Adjustment” clockwise slowly to
change the response time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
4. Field Flashing
When the regulator is operated with the generator for
the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
1. With the Prime-mover at rest and the regulator’s
field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
2. Allow approximately 3 seconds before removing
the DC source.
3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
4. If repeating steps a. and b. does not result in
generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

Package Including:
1 × Automatic Voltage Regulator Controller AVR EA05A Genset Parts
1×Product Instructions

Item SpecificsCountry of Origin :United StatesBrand :Tool libraryMPN :EA05AType :Automatic Voltage RegulatorQuantity :1 PCModel :EA05AEquipment Type :Voltage RegulatorWarranty :1 Year
Payment

Once payment is cleared, we will arrange for shipment as soon as possible to ensure your item arrives on time

Shipping

1.Usually your Items will be shipped within 1-3 business day after your payment is cleared.
International orders may take 10 to 30 business days to arrive.
2.We have CA, NJ warehouses and ship items may vary according to the stock.
3.No shipping on Weekends or US Public Holidays.

Returns

We now offer for US buyers 30 days money back guarantee . If US buyers does not like the item or feels not satisfied with the product, we will cover the return shipping fee & US buyer can return the item and get refund for item price only.

Contact Us

If there are any defects or issues with the product, we will resolve them for you as soon as possible. Thank you for your understanding and support.

response

We offer high quality products, competitive prices and prompt delivery .Please add us to your list of favorite sellers. Our company has experience in serving the global aftermarket. Thank you for your business. Best wishes!


All rights reserved.


On Nov 25, 2026 at 22:02:47 PST, seller added the following information:

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design