AES 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber 8-Zone 7794A IntelliPro Tested
$749.00

OVERVIEW AES Corporation IntelliNet 2.0 Fire Subscriber, model 7707P-88-ULP-M. This is a supervised wireless fire alarm communicator that transmits alarm, supervisory and trouble signals from a fire alarm control panel to a central station over the AES 450-470 MHz mesh radio network, with Ethernet IP as a second path. The -ULP designation means the 7794A AES-IntelliPro full data module is factory installed, allowing transmission of full zone and event data rather than consolidated signals. The -M designation adds Multiple Communication Technologies. TESTED & WORKING STATUS Bench power-on test performed and photographed. - VERIFIED: unit powers up and boots to the AES splash screen, then runs to the operating status display.
- VERIFIED: firmware reports 7707 FIRE V7.2.10. This is newer than the v7.2.02 threshold below which AES requires factory update files.
- VERIFIED: panel menu reports Panel Interface: 7794A VER 4.026, confirming the IntelliPro full data module is installed and communicating with the mainboard.
- VERIFIED: green POWER LED, amber TROUBLE LED, and backlit LCD all function. No dead LCD segments.
- Unit reports one fault only: BATTERY FAIL. This is the expected supervisory indication when no backup battery is connected and is not a fault of the unit.
- NOT VERIFIED: RF radio transmission, mesh network registration, Ethernet connectivity, and zone input response. No antenna was fitted and the unit was not registered to a 8 supervised dry-contact inputs via installed 7711 zone input card, 2.2k EOL
- Firmware: V7.2.10
- Data module: 7794A AES-IntelliPro, VER 4.026, module dated 2024-01-22
- Radio: AES IntelliNet mesh, factory tuned to 465.9375 MHz, 2 watts, 12.5 kHz channel spacing
- Secondary path: Ethernet
- Programming: smartphone, tablet, laptop or onboard USB
- Display: backlit LCD, Power and Trouble LEDs, Menu/Silence button
- Input power: 16.5 VAC, 60 Hz, 40 VA, Class 2
- Backup battery: 12 Ah recommended when 7794A is fitted (not included)
- Listings: UL and ULC, 35PB, NFPA code compliant
- Serial: 0080229
CONDITION Unused and never commissioned, opened for inspection and bench testing. Enclosure paint clean with no dents, scuffs or rack rash. Lock and key present and functional. All terminal screws untouched. Boards free of flux residue, marker, staging dots or field markings. A previous-owner asset sticker is applied to the enclosure side. Carton is opened and retaped with light edge wear. The BATTERY FAIL status shown in the listing photos is the normal supervisory response to an absent backup battery and clears when a battery is with commercial fire alarm control panels via dry relay contacts on the 8 supervised zone inputs. Requires an active AES IntelliNet mesh network and a dealer monitoring account. The radio transceiver is factory tuned to 465.9375 MHz. AES supplies these radios tuned to a dealer's authorized frequency and states they can be retuned for takeover accounts, so a different network frequency is a retuning question rather than an incompatibility - but retuning is an AES factory or authorized-dealer operation, not a field adjustment. If you need a drop-in with no retune, confirm your network operates on 465.9375 MHz. This seller also stocks matching 465.9375 MHz spare transceivers and alternate-frequency AES transceiver modules, listed separately. WHAT'S INCLUDED - 7707P-88-ULP-M subscriber in red steel enclosure, 7794A and 7711 installed
- 1640-ENCL transformer enclosure with keyset, mounting hardware, 8x 2.2k EOL resistor leads
- AES 1640 16.5 VAC 40 VA Class 2 transformer (added from separate stock)
- 7711 installation and operation manual
- NO ANTENNA INCLUDED - the AES 7214 rubber duck antenna is not present
- No backup battery, no Ethernet cable, no fire alarm panel
INSTALLATION & LIABILITY Installation must be performed by a licensed fire alarm contractor in accordance with NFPA 72 and all applicable local codes. This unit has been bench power-on tested only as described above; it is otherwise untested and is not certified for service. It was opened for inspection and photography. Radio subscribers are network- and account-dependent; verify frequency, software version and network compatibility with AES Corporation and your monitoring provider before purchase. No manufacturer warranty is offered. Shipping Policy We ship within 3 business day of payment. All items are carefully packed. Returns 30-day returns accepted. Item must be in original condition. Contact Message us with any questions before purchasing.