Free Userbar - Userbars - User Bar - User Bars
 
Advanced search
Registered users

Username:

Password:

Log me on automatically next visit?

¬ Forgot password
¬ Registration

» Upload Userbar
» Animate Userbar
» Userbars Tutorial
» Userbar Tournaments
» Forum
» Chat Room
» FAQ
» Links

• PC Cheat Codes

>> If you dont know how to design a userbar, then write here a Userbar that you want. >> If you know how to design them help these people and design what they request.




USERBARS.org | Free Forum Userbars

On eBay now
eBay

AC80-260V 10A/100A Communication Module Used for Measuring Voltage Current Power

AC80-260V 10A/100A Communication Module Used for Measuring Voltage Current Power
$14.21

Buy Now

PZEM-014/016 AC communication moduleOverview:

This document describes the specification of the PZEM-014/016 AC communication module, the module is mainly used for measuring AC voltage, current, active power, frequency, power factor and active energy, the module iswithout display function, the data isread through the RS485 interface.

PZEM-014: Measuring Range10A (Built-in Shunt)

PZEM-016: Measuring Range 100A (external transformer)

1.Function description:
  • 1.1Voltage

  • 1.1.1Measuring range:80~260V

  • 1.1.2Resolution: 0.1V

  • 1.1.3Measurement accuracy: 0.5%

  • 1.2Current
  • 1.2.1Measuring range:0~10A(PZEM-014); 0~100A(PZEM-016)\\

  • 1.2.2Starting measure current: 0.01A(PZEM-014); 0.02A(PZEM-016)

  • 1.2.3Resolution: 0.001A

  • 1.2.4Measurement accuracy: 0.5%

  • 1.3Active powe

  • 1.3.1Measuring range:0~2.3kW(PZEM-014); 0~23kW(PZEM-016)

  • 1.3.2Starting measure power: 0.4W

  • 1.3.3Resolution: 0.1W

  • 1.3.4Display format:

    • When the data is <1000W, it display one decimal, such as: 999.9W;
    • When the data is ≥1000W, it display only integer, such as: 1000W
  • 1.3.5Measurement accuracy: 0.5%

  • 1.4Power factor
  • 1.4.1Measuring range:0.00~1.00

  • 1.4.2Resolution: 0.01

  • 1.4.3Measurement accuracy: 1%

  • 1.5Frequency
  • 1.5.1Measuring range:45Hz~65Hz

  • 1.5.2Resolution: 0.1Hz

  • 1.5.3Measurement accuracy: 0.5%

  • 1.6Active energy
  • 1.6.1Measuring range: 0~9999.99kWh

  • 1.6.2Resolution: 1Wh

  • 1.6.3Measurement accuracy: 0.5%

  • 1.6.4Display format:

    • When the data is <10kWh, the display unit is Wh(1kWh=1000Wh), such as: 9999Wh;

    • When the data is ≥10kWh, the display unit is kWh, such as: 9999.99kWh

  • 1.6.5Reset energy: use software to reset.

  • 1.7Over power alarm
  1. Active power threshold can be set, when the measured active power exceeds the threshold,it canalarm
  • 1.8Communication interface
    • RS485 protocol

      2.1Physical layer protocol

      Physical layer useUART to RS485 communication interface

      Baud rate is 9600, 8 data bits, 1 stop bit, no parity

      2.2Application layer protocol

      The application layer use the Modbus-RTU protocol to communicate. At present, it only supports function codes such as 0x03 (Read Holding Register), 0x04 (Read Input Register), 0x06 (Write Single Register), 0x41 (Calibration), 0x42 (Reset energy).etc.

      0x41 function code is only for internal use (address can be only 0xF8), used for factory calibration and return to factory maintenance occasions, after the function code to increase 16-bit password, the default password is 0x3721

      The address range of the slave is 0x01 ~ 0xF7. The address 0x00 is used as the broadcast address, the slave does not need to reply the master. The address 0xF8 is used as the general address, thisaddress can be only used in single-slave environment and can be used for calibrationetc.operation.

      2.3Read the measurement result

      The command formatof the masterreads the measurement result is(total of 8 bytes):

      Slave Address + 0x04 + Register Address High Byte + Register Address Low Byte + Number of Registers High Byte + Number of Registers Low Byte + CRC Check High Byte + CRC Check Low Byte.

      The command formatof the replyfrom the slaveis divided into two kinds:

      Correct Reply: Slave Address + 0x04 + Number of Bytes+ Register 1 Data High Byte + Register 1 Data Low Byte + ... + CRC Check High Byte + CRC Check Low Byte

      Error Reply: Slave address + 0x84 + Abnormal code + CRC check high byte + CRC check low byte

      Abnormal code analyzedas following(the same below)

      • 0x01,Illegal function
      • 0x02,Illegal address
      • 0x03,Illegal data
      • 0x04,Slave error

      Theregister of themeasurement results isarranged as the following table

      Register address

      Description

      Resolution

      0x0000

      Voltage value

      1LSBcorrespondto 0.1V

      0x0001

      Current valuehigh 16 bits

      1LSBcorrespondto 0.001A

      0x0002

      Current valuelow 16 bits

      0x0003

      Power valuehigh 16 bits

      1LSBcorrespondto 0.1W

      0x0004

      Power value low16 bits

      0x0005

      Energy value high16 bits

      1LSBcorrespondto 1Wh

      0x0006

      Energy value low16 bits

      0x0007

      Frequency value

      1LSBcorrespondto 0.1Hz

      0x0008

      Power factor value

      1LSBcorrespondto 0.01

      0x0009

      Alarm status

      0xFFFF is alarm,0x0000is not alarm

      For example, the mastersends the following command (CRC checkcode is replaced by0xHH and 0xLL, the same below)

      0x01 + 0x04 +0x00+0x00+0x00+0x0A+ 0xHH + 0xLL

      Indicates that the masterneeds to read 10 registers with slave address 0x01 and the start address of the register is 0x0000

      The correct reply from the slaveis as following:

      0x01 + 0x04 + 0x14 +0x08+ 0x98+0x00+ 0x00 + 0x03+ 0xE8+0x00+ 0x00 + 0x08+ 0x98+0x00+ 0x00+ 0x00+ 0x00+0x01+ 0xF4+0x00+ 0x64+0x00+ 0x00+ 0xHH + 0xLL

      The above data shows

      • Voltageis0x0898, converted to decimalis2200, display220.0V
      • Current is0x000003E8, converted to decimalis1000, display1.000A
      • Power is 0x00000898,converted to decimalis 2200, display 220.0W
      • Energy is 0x00000000,converted to decimalis 0, display 0Wh
      • Frequency is 0x01F4,converted to decimalis 500, display 50.0Hz
      • Power factor is 0x0064,converted to decimalis 100, display 1.00
      • Alarm status is 0x0000, indicates that the current power is lower than the alarm power threshold

      2.4Read and modify the slave parameters

      At present,itonly supports reading and modifying slave address and power alarm threshold

      The register is arrangedas the following table

      Register address

      Description

      Resolution

      0x0001

      Power alarm threshold

      1LSBcorrespondto 1W

      0x0002

      Modbus-RTU address

      The range is 0x0001~0x00F7

      The command format of the masterto read the slave parameters and read the measurement results are same(described in detailsin Section 3.3), only need to change the function code from 0x04 to 0x03.

      The command format of the masterto modify the slave parameters is (total of 8 bytes):

      Slave Address + 0x06 + Register Address High Byte + Register Address Low Byte + Register Value High Byte + Register Value Low Byte + CRC Check High Byte + CRC Check Low Byte.

      The command formatof the replyfrom the slaveis divided into two kinds:

      Correct Response: Slave Address + 0x06 + Number ofBytes + Register Address Low Byte + Register Value High Byte + Register Value Low Byte + CRC Check High Byte + CRC Check Low Byte.

      Error Reply: Slave address + 0x86 + Abnormal code + CRC check high byte + CRC check low byte.

      For example, the mastersets the slave\'s power alarm threshold:

      0x01 + 0x04 +0x00+ 0x01+0x08+ 0xFC+ 0xHH + 0xLL

      Indicates that the masterneeds to set the 0x0001 register (power alarm threshold) to 0x08FC (2300W).

      Set up correctly, the slave return to the data which is sent from the master.

      For example, the mastersets the address of the slave

      0x01 + 0x04 + 0x00+ 0x02+ 0x00+ 0x05+ 0xHH + 0xLL

      Indicates that the masterneeds to set the 0x0002 register (Modbus-RTU address) to 0x0005

      Set up correctly, the slave return to the data which is sent from the master.

      2.5Reset energy

      The command format of the master to resetthe slave\'s power is (total 4 bytes):

      Slave address + 0x42 + CRC check high byte + CRC check low byte.

      Correct reply: slave address + 0x42 + CRC check high byte + CRC check low byte.

      Error Reply: Slave address + 0xC2 + Abnormal code + CRC check high byte + CRC check low byte

      2.6Calibration

      The command format of the masterto calibrate the slave is (total 6 bytes):

      0xF8 + 0x41 + 0x37 + 0x21 + CRC check high byte + CRC check low byte.

      Correct reply: 0xF8 + 0x41 + 0x37 + 0x21 + CRC check high byte + CRC check low byte.

      Error Reply: 0xF8 + 0xC1 + Abnormal code + CRC check high byte + CRC check low byte.

      It should be noted that the calibration takes 3 to 4 seconds, after the mastersends the command, if the calibration is successful, it will take3 ~ 4 seconds to receive the response from the slave.

      2.7 CRC check

      CRC check use16bits format, occupy two bytes, the generator polynomial is X16 + X15 + X2 +1, the polynomial value used for calculation is 0xA001.

      The value of the CRC check is a frame data divide all resultsof checking all the bytes except the CRC check value.


      3.Other instructions

      3.1Power supply

      AC voltage provides two isolated outputs after through the switching power supply, oneway is3.3Vprovides to themeasurement system, the other way is 5V provides to485 communication circuits and external circuits.

      485 communication interface power is(+5 V),current output capability is 100mA

      3.2Working temperature

      -20℃~ +60℃

      Package include:
      • PZEM-014(10A without CT)
        • 1 xCommunication Module

        • 1 xUSB to 485Module
        • 1 x English User Manual

      • PZEM-016(100A with CT)

        • 1 xCommunication Module

        • 1xCurrent Transformer

        • 1 xUSB to 485Module

        • 1 x English User Manual





Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Popular Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design