|
>> If you dont know how to design a userbar, then write here a Userbar that you want.
>> If you know how to design them help these people and design what they request.
|
 |
 |
USERBARS.org | Free Forum Userbars
| On eBay now |
ABB OT40F3 Switch Disconnector 1SCA104902R1001 3-pole, front operated
$33.50

DimensionsProduct Net Width:35 mmProduct Net Height:68 mmProduct Net Depth / Length:56 mmProduct Net Weight:0.09 kgTechnicalRated Operational Current AC-21A (Ie):(380 ... 415 V) 40 A(500 V) 40 A(690 V) 40 ARated Operational Current AC-22A (Ie):(380 ... 415 V) 40 A(500 V) 40 A(690 V) 40 ARated Operational Current AC-23A (Ie):(380 ... 415 V) 23 A(500 V) 23 A(690 V) 12 ARated Operational Power AC-23A (Pe):(220 ... 240 V) 5.5 kW(400 ... 415 V) 11 kW(500 V) 11 kW(690 V) 11 kWConventional Free-air Thermal Current (Ith):Θ = 40 °C 40 AConventional Thermal Current (Ithe):Fully Enclosed 40 ARated Impulse Withstand Voltage (Uimp):8 kVRated Insulation Voltage (Ui):acc. to IEC/EN 60664-1 750 VRated Operational Voltage:Main Circuit 750 VRated Short-Circuit Making Capacity (Icm):(690 V) 0.71 kARated Short-time Withstand Current Low Voltage (Icw):for 1 s 0.5 kARated Conditional Short-Circuit Current (Inc):(40 A fuse, ≤415V) 50 kA(25 A fuse, 690 V) 50 kAPower Loss:at Rated Operating Conditions per Pole 1.6 WPollution Degree:3Handle Type:KnobHandle and shaft not includedSwitches Operating Mechanism:Mechanism on Top of the SwitchDistance Between Phases:StandardPosition of Line Terminals:Top In - Bottom OutBottom In - Top OutOperating Mode:Front operatedStandards:IEC 60947-3 / UL 508 / CSA C22.2 No. 14Special Functions:NoMounting Type:Base mountingNumber of Poles:3Cable Cross-Section:Cu 0.75 ... 10 mm²Wire Stripping Length:Main Circuit 10 mmMain Circuit 0.38 inDegree of Protection:Front IP20Terminal Type:Screw TerminalsTightening Torque:acc. IEC 60947-1 0.8 N·mMechanical Durability:20000Lock Type:NoTechnical UL/CSAMaximum Operating Voltage UL/CSA:600 VAmpere Rating:40 AHorsepower Rating UL/CSA:(110 ... 120 V AC) Single Phase 2 Hp(240 V AC) Single Phase 5 Hp(440 ... 480 V AC) Single Phase 10 Hp(550 ... 600 V AC) Single Phase 15 Hp(220 ... 240 V AC) Three Phase 10 Hp(440 ... 480 V AC) Three Phase 20 Hp(550 ... 600 V AC) Three Phase 25 HpWire Stripping Length:Main Circuit 10 mmMain Circuit 0.38 inTightening Torque:acc. IEC 60947-1 0.8 N·mTightening Torque UL/CSA:7 in·lb

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
|
|
|
 |
 |
|