6kw Oil-type Mold Temperature Controller for Injection Molds 200-240V

6kw Oil-type Mold Temperature Controller  for Injection Molds  200-240V
$1,344.20

Buy Now

Product Overview  

6KW Oil Type Mold Temperature Controller Machine Plastic/Chemical Industry 200-240V 3PH

Product Overview The KMW-610Y Oil Mold Temperature Regulator is a direct-drive oil-type thermoregulator designed for precise temperature control of mold and die surfaces in injection molding, extrusion, and related industrial applications. It maintains the mold at a stable operating temperature by circulating heated thermal oil through the mold channels, thereby improving product quality, reducing cycle time, and minimizing defects caused by temperature variation.
The unit features an integrated heating system, a direct-drive circulating pump, and a digital control panel with programmable temperature settings and multiple safety protections. The heating barrel is constructed from 304 stainless steel seamless tubing, offering resistance to corrosion and reduced internal scaling. Product Parameters Voltage / Frequency 200-240V AC / 60Hz, Three-Phase (factory-configured 220V 60Hz) Heater Power 6 kW Pump Power 0.75 kW Total Power 6.75 kW Heat Transfer Medium Thermal Oil (oil and water must not be mixed) Operating Temperature Range 20℃ ~ 180℃ (adjustable) (68℉ ~ 356℉) Pump Flow Rate 56 L/min (14.8 gal/min) Pump Working Pressure 2 kg/cm² Circulation Hose Size 3/8\" (0.95 cm), 4-in 4-out Heating Barrel Material 304 Stainless Steel Seamless Tube Package size: 34.65\"*16.14\"*30.71\" (88cm*41cm*78cm) Net weight / Gross weight: 80.5lbs(36.5kg) / 117.95lbs(53.5kg) Precautions WARNING: Failure to observe the following precautions may result in personal injury, fire, or equipment damage.

1.Read this manual carefully and familiarize yourself with machine performance and operating methods before use.

2.The machine must be operated by trained personnel only. Untrained individuals are prohibited from operating the equipment.

3.Ensure the machine is properly grounded before operation. Do not operate if the ground connection is missing or compromised.

4.Use only the recommended thermal oil. Never mix oil and water in the system, as this will cause severe damage and potential explosion.

5.Do not exceed the maximum operating temperature of 180℃ . Operating above this limit may damage the heating element and oil.

6.Do not open the oil fill port or drain valve while the machine is at high temperature. Allow the oil to cool below 60℃ first.

7.Ensure the oil level is always within the normal range before starting the machine. Operating with insufficient oil will trigger the Er02 protection and may damage the pump.

8.Keep flammable materials away from the machine. The heating element and thermal oil reach high temperatures during operation.

9.If a fault code appears on the display, stop the machine immediately and resolve the issue before restarting. Refer to the Troubleshooting section for guidance.

10.When inspecting or maintaining the machine, disconnect the main power supply and allow the oil temperature to decrease to a safe level.

11.Periodically inspect the circulation hoses and connections for oil leaks. Address any leakage promptly.

12.Do not modify the machine wiring, control parameters, or safety devices. Any unauthorized modification voids warranty and may create hazards.

Product Features & Advantages

Emergency Stop Switch
The emergency stop switch is a key safety device of the mold temperature controller. Once triggered, it immediately cuts off the main power supply to the equipment, bringing all operating components such as the heater and pump to an instantaneous stop. This achieves an emergency shutdown, prevents accident escalation, and protects operator safety as well as the mold and equipment from further damage.

Standardized Interface – Safe & Leak-Proof
The ‌\"Mold Outlet\" and \"Mold Inlet\" feature industry-standard threaded connections, enabling quick and secure assembly. These interfaces are made from robust, durable materials and equipped with precision-machined sealing surfaces, effectively preventing leakage at connection points. Even under high temperature and high pressure, they ensure long-term reliability and stable operation.

Control Panel
The PID control algorithm enables automatic adjustment of heating and cooling intensity and duration based on the deviation between the set target temperature and the actual temperature, thereby achieving high-precision, low-fluctuation temperature control. Combined with high-precision sensors and a clear digital display, operators can intuitively view and set temperature parameters, simplifying the operation process. This user-centered design combines ease of operation with powerful functionality, thereby achieving efficient management.

 

Easy Mobility and Stable Positioning
The equipment is equipped with four swivel casters on the bottom, two of which are fitted with brake locks. This design allows the equipment to be moved easily and flexibly to the desired location within the workshop. Once in position, engaging the brake locks ensures that the equipment remains stable and stationary during operation, thereby ensuring safety and stable performance.

Efficient Airflow Design for Stable Performance
The machine features a large number of ventilation openings on the housing, forming efficient airflow paths. This design quickly dissipates heat generated by the internal electrical control system and heating devices, effectively preventing performance degradation or shutdown caused by overheating. Even under continuous high-load operation, it ensures precise and stable temperature control.

 

- Oil-type mold temperature controller: Uses heat transfer oil as the medium, suitable for higher temperature applications.

- Heating cylinder: Made of 304 stainless steel seamless pipe to reduce pipe resistance and rust scale.

- PID control for heating/cooling operations to regulate the medium temperature and achieve high-precision temperature control.
- Safety protection functions: phase loss protection, low fluid alarm, overheat protection, overload protection, etc.
- Audible alarm and indicator lights: heating indicator light, pump overload protection flashing indicator light, phase reversal indicator light, low liquid level indicator light for easy operation.
- Programmable timer: allows setting automatic start/stop time for unattended operation.

Operating Instructions

Power-On Procedure

1.Ensure the machine is properly connected to power, oil is filled to the correct level, and all hose connections are secure.

2.Press the green Start button. The control panel will initialize and display the current temperature.

3.Wait for the Pump indicator light to illuminate, confirming the circulation pump is running.

4.Verify that no fault codes (Er01~Er08) appear on the display.

 

Temperature Setting

5.Press the Function key to enter the parameter setting mode.

6.Use the Up and Down keys to navigate to the temperature setpoint parameter.

7.Adjust the target temperature to the desired value within the 20℃ ~180℃ range.

8.Press the OK key to confirm and save the setting.

9.The machine will automatically begin heating once the setpoint is confirmed, and the Heat indicator light will illuminate during active heating.

 

Normal Operation

10.During normal operation, the pump continuously circulates thermal oil between the machine and the mold.

11.The heater activates when the actual temperature is below the setpoint and deactivates when the setpoint is reached.

12.The Cool indicator light illuminates when the cooling function is active (if cooling water is connected and enabled).

13.Monitor the digital display for the current temperature. Allow sufficient time for the mold to reach thermal equilibrium after the machine reaches the setpoint.

14.Do not block the ventilation openings on the cabinet during operation.

 

Shutdown Procedure

15.Press the red Stop button to halt the heater and pump.

16.If the machine will not be used for an extended period, allow the oil temperature to decrease below 60℃ before disconnecting power.

17.Close any external cooling water valves if applicable.

18.Disconnect the main power supply if the machine will be idle for more than 24 hours.

Product Presentation & Details Item Included (053402)

6KW Oil Type Mold Temperature Controller Machine Plastic/Chemical Industry 200-240V 3PH*1

You can make order with no worry.
Any concern just feel free to let us know, we\'ll reply in 24 hours in normal condition.
Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders are processed from Monday-Friday; Not on the weekends & public holidays.
Warranty: 6 months\' warranty for the machines, not for the consumables.
We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost.

新建网页 6新建网页 1

Shipping & Handling Details

Default Shipping Cost or Free Shipping Information:

▲Default shipping cost or free shipping service is only for the customers from Canada or the lower 48 United States by Canada Post, USPS or the UPS Ground. Customers from other areas or needs other shipping ways, please contact us.
▲Buyers from Guam, Puerto Rico, Virgin Islands, American Samoa, Alaska, Hawaii, PO Boxes, APO/FPO addresses or other countries/areas,there WILL be extra shipping costs, please contact us for more detailed information.
▲Please make sure your address is valid for both UPS and USPS services. Any costs incurred because of incorrect or undeliverable address should be undertaken by buyer.

Handling Time:Shipping is usually made in 1-3 business days after payments cleared. Orders are processed fromMonday-Friday; Not on the weekends & public holidays.

Sales tax / Customs duties:Any sales taxes or Customs duties are not included. If came out, they must be undertaken by the buyer.

Damage In Shipping:Email or call us First! We will work with you to get the case resolved in the fastest method.

Return / Refund

If you are not 100% happy with your purchase, please contact Us. Please don\'t directly opened a request or case without informing us, or else, we will do some discounts on the warranty and other sales-services later on. Hope for your understanding.

Returns & Exchanges

▲All returns must be made within 14 days of delivery date. Items must be in new, unused condition, with all original materials included with the shipment. A partial refund may be applied for opened or damaged items, depending on the condition.
▲Items returned under the buyer’s remorse: The return shipping fee must be covered by the buyer; The original shipping cost will also be deducted from the refund. 15% restocking fee of the items purchase price will be charged.
▲Returns that are the result of our seller\'s error: Buyer will receive a full refund of the item as well as shipping charges
▲All returns require a RA (Return Authorization) number that will be given by our seller. Please contact with us at first for more details.

Defective & Damaged Products

▲If product was received damaged or not as described, please send us some pictures or videos, so we could well understand your problem, then solve them for you ASAP. Besides, it\'s much helpful for us to claim with UPS, remind our related department to pay much more attention to packaging later on. Hope for your understanding.
▲Replacement or refund of defective or damaged products can only be returned in exchange for the exact same product, or else, the purchase price will be refunded back to your original payment method.
▲If an item is received damaged, customer service must be contacted within 7 days of receiving your item. All returns require a RA (Return Authorization) number as above.

Payment

eCheck Issues:Payments via eCheck do not clear immediately. Usually you will wait 5-7 days after checkout for it to clear. Then we will arrange shipments for you.

Warranty & response

▲6 months\' warranty for the machines, not for the consumables. We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost.
▲Any warranty shipping cost to us is responsible by buyer.
▲Any shipping cost to buyer is responsible by the seller.
▲We committee to the customer satisfaction and want to bring you the best purchase experience. If there is any problems, please contact us ASAP. If not, please leave us a positive response as it\'s very important for us. Thanks very much.

a

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design