Technical Specs | 220V Coal Calorific Value Testing Instrument Auto Calorimeter Built-in Printer 220V Coal Calorific Value Testing Instrument Auto Calorimeter Built-in Printer The precision fully automatic calorimeter is mainly used by heat detection institutions and coal standard analysis to determine the calorific value of combustibles. The embedded calorimeter is widely applied in various industries such as coal testing, petroleum, chemical industry, wood, scientific research and food. Product Parameter: Ignition voltageAC 220V Ignition time3-6 seconds (automatic) Instrument power30W Reference heat capacityApproximately 10500J/K External water tank capacityApproximately 40L (10.5 us gal) Internal water tank capacityApproximately 2.1L (0.5 us gal) Temperature measurement range0.0000°C-40.0000°C Resolution0.0001°C Operating environmentRoom temperature: 5-40°C (The room temperature variation measured each time should be ≤1°C.)
Relative humidity: ≤85% Precaution:
- 1. When connecting the instrument, please disconnect the power supply. Do not perform any wiring operations while the instrument is powered on.
- 2. Do not apply excessive pressure to the LCD screen. Excessive pressure may cause the LCD screen to be broken or damaged.
- 3. Do not use sharp objects to touch or scratch the liquid crystal touch screen. Otherwise, the LCD screen may be damaged.
- 4. The temperature control instrument must be reliably grounded to prevent electric leakage and accidental electric shock.
- 5. Keep away from flammable, explosive, corrosive, radioactive and other items and environments to prevent damage to the instrument or reduction of its lifespan and avoid accidents.
- 6. Try to keep the instrument\'s usage environment clean. Avoid dust. Otherwise, there is a risk of damaging the instrument.
Features:
- 1. The modular 24-bit AD temperature acquisition circuit is adopted, ensuring temperature measurement accuracy to one part in ten thousand.
- 2. The temperature measurement module adopts electronic components with ultra-low temperature drift characteristics, ensuring the stability of test results.
- 3. The machine uses an embedded ARM as the main control chip, and is equipped with a true-color touch LCD screen, achieving simpler and more flexible operation. The direct human-machine interaction method makes use more convenient.
- 4. The machine has powerful data processing capabilities of the computer and strong extensibility, and realizes a perfect expression of the instrument. Querying and printing of historical data become easy and effortless, and the compatibility possibility for future equipment networking and data sharing is provided.
- 5. Real-time cooling correction has low requirements for environmental temperature. Sulfur, hydrogen and water data can be supplemented and input after testing and automatically converted into high and low calorific values, and are more conform to the conventional experimental process.
- 6. The experimental process of adding water, discharging water, stirring, igniting, measuring temperature, calculating, correcting and printing is fully automatic, avoiding human errors, and significantly improving accuracy and precision.
- 7. The display platform adopts a large-sized color LCD touch screen display, providing rich, intuitive and clear information display, and supporting the review of files or documents. Operators can view the national standard requirements for coal test methods, experimental methods, experimental steps, etc.
- 8. The equipment is designed in an integrated form, and features convenient installation and replacement, and more reliable performance.
Working Chamber The polished working chamber enables uniform heat exchange and reduces heat loss to improve calorific value test accuracy. It features strong anti-interference performance and excellent repeatability. Stirring Unit The stirrer unit is made of temperature-resistant and anti-corrosion materials, which mixes water evenly and balances water temperature rapidly to improve temperature measurement accuracy. Control System The machine is equipped with a high-definition touch screen and built-in mini printer. The touch interface enables easy operation for real-time data viewing, parameter setting and historical record query. The integrated printer supports one-click printing of test reports. Heat Dissipation Holes The elongated ventilation holes rapidly dissipate heat generated inside the device, lower the working temperature of the electronic control system, prevent component aging caused by overheating, and extend the service life of the whole machine. Oxygen Bomb The oxygen bomb is made of high-strength mirror-polished materials, and features pressure resistance, explosion-proof performance and corrosion resistance. The threaded locking structure provides reliable sealing without leakage after high-pressure oxygen filling. Oxygen Filling Device The oxygen filling device is specially designed for oxygen bomb filling of the calorimeter. It provides stable pressure regulation and simple operation. It can fill oxygen into the oxygen bomb quickly and smoothly and keep the consistent oxygen pressure for each test. Operation Method:
- 1. Power On: Turn on the machine power to enable the machine to enter the working state.
- 2. Open the oxygen bomb, clean the oxygen bomb cup, crucible, ignition column and other parts, and then add 10mL of room temperature distilled water to the oxygen bomb cup.
- 3. Place the oxygen bomb head on the oxygen bomb stand, install the ignition wire (the ignition wire should be firmly installed to ensure reliable electrical contact with the ignition electrodes, and the length of the ignition wire between the two electrodes should be consistent), and then tie the ignition cotton thread in the middle of the ignition wire.
- 4. Put the weighed sample (weighing accuracy to 0.0001mg) in the crucible into the crucible position below the ignition electrodes and then insert one end of the ignition cotton thread into the coal sample, but do not take out the coal powder. (If it is the benzoic acid tablet for heat capacity calibration, just press the cotton thread).
- 5. Carefully tighten the oxygen bomb nut. After that, the oxygen bomb should be handled gently to prevent the cotton thread from falling off, which may cause ignition failure.
- 6. Open the oxygen cylinder valve, adjust the pressure reducer output pressure to 2.8-3MPa. Then, fill the oxygen bomb to this pressure in no less than 15 seconds and place it on the oxygen bomb fixing base in the calorimeter inner cylinder (when the oxygen filling pressure is greater than 3.2MPa, the operate should release the oxygen, adjust the pressure and then refill the oxygen again).
- 7. Select the calorific value data input interface or heat capacity data input interface according to the sample for calorific value testing or the system heat capacity calibration of benzoic acid. Correspondingly input the required data and then start the experiment.
- 8. After the experiment is completed, remove the oxygen bomb, release the pressure, and check if there is any sample splashing inside the oxygen bomb. If so, this test is invalid. The final result data will be given on the screen and by the printer. If you need to conduct another experiment, repeat the steps in sequence.
Item Number: 1 x Coal Calorific Value Testing Instrument 220V (021164) Shipping & Handling Details Default Shipping Cost or Free Shipping Information: ▲ Default shipping cost or free shipping service is only for the customers from Canada or the lower 48 United States by Canada Post, USPS or the UPS Ground. Customers from other areas or needs other shipping ways, please contact us.
▲ Buyers from Guam, Puerto Rico, Virgin Islands, American Samoa, Alaska, Hawaii, PO Boxes, APO/FPO addresses or other countries/areas, there will be extra shipping costs, please contact us for more detailed information.
▲ Please make sure your address is valid for both UPS and USPS services. Any costs incurred because of incorrect or undeliverable address should be undertaken by buyer. Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders are processed from Monday-Friday; Not on the weekends & public holidays. Sales tax / Customs duties: Any sales taxes or Customs duties are not included. If came out, they must be undertaken by the buyer. Damage In Shipping: Email or call us First! We will work with you to get the case resolved in the fastest method. Return / Refund If you are not 100% happy with your purchase, please contact Us. Please don\'t directly opened a request or case without informing us, or else, we will do some discounts on the warranty and other sales-services later on. Hope for your understanding. Returns & Exchanges
▲ All returns must be made within 30 days of delivery date. Items must be in new, unused condition, with all original materials included with the shipment. A partial refund may be applied for opened or damaged items, depending on the condition.
▲ Items returned under the buyer’s remorse: The return shipping fee must be covered by the buyer; The original shipping cost will also be deducted from the refund. 15% restocking fee of the items purchase price will be charged.
▲ Returns that are the result of our seller\'s error: Buyer will receive a full refund of the item as well as shipping charges.
▲ All returns require a RA (Return Authorization) number that will be given by our seller. Please contact with us at first for more details. Defective & Damaged Products
▲ If product was received damaged or not as described, please send us some pictures or videos, so we could well understand your problem, then solve them for you ASAP. Besides, it\'s much helpful for us to claim with UPS, remind our related department to pay much more attention to packaging later on. Hope for your understanding.
▲ Replacement or refund of defective or damaged products can only be returned in exchange for the exact same product, or else, the purchase price will be refunded back to your original payment method.
▲ If an item is received damaged, customer service must be contacted within 7 days of receiving your item. All returns require a RA (Return Authorization) number as above. Warranty & response ▲ 6 months\' warranty for the machines, not for the consumables. We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost.
▲ Any warranty shipping cost to us is responsible by buyer.