On eBay now
eBay

X-Rite i1 Pro 3 Spectrophotometer Color Calibration Device

X-Rite i1 Pro 3 Spectrophotometer Color Calibration Device
$1,599.94

Buy Now

X-Rite i1 Pro 3 Spectrophotometer Color Calibration KitCondition
  • Excellent overall condition. Shows light signs of prior use (minor cosmetic wear).
  • Original packaging and pictured accessories included. USB cable is missing.
  • No software, license, or calibration certificates included.
What\'s Included
  • X-Rite i1Pro 3 spectrophotometer
  • Fitted carrying case
  • Calibration base / holder
  • Monitor holder
  • Scanning ruler / guide
  • Backer board
  • ColorChecker / proofing materials shown
  • Documentation / quick-start materials
  • Certificate of Performance
  • No additional accessories or software unless shown
Shipping
  • Free shipping via Fedex or UPS Ground service
    • Please note we do not currently ship to mail forwarders nor PO boxes.
  • Free 1-day handling for shipping.
  • Signature will be required. No exceptions can be made.
Returns
  • Free returns only offered if the item is returned in original condition (i.e the factory seal is not broken)
  • A minimum restocking fee of 20% applies if the factory seal is broken
Manufacturer Specifications:
System RequirementsMacMac OS X 10.13x, 10.14x or 10.15x
512 MB RAM (2 GB Recommended)
Intel Core Duo Processor
500MB of Available Disk Space
Powered USB Port
Monitor Resolution of 1024 x 768 Pixels or Higher
DVD Drive or Internet Connection Required for Software Install, Download, and Automatic Software UpdateWindowsMicrosoft Windows 10, 8.1, 8, or 7 (32- or 64-Bit) with Latest Updates and Service Packs Installed
512 MB RAM (2 GB Recommended)
Intel Core 2 Duo or AMD Athlon XP or Better CPU
500 MB of Available Disk Space
Powered USB Port Monitor Resolution of 1024 x 768 Pixels or Higher
DVD Drive or Internet Connection Required for Software Install, Download, and Automatic Software UpdateHardware SpecificationsSpectral Rangei1 Technology with Built-In Wavelengths Check
Spectral Analyzer: Holographic Diffraction Grating with 128-Pixel Diode Array
Spectral Range: 380-730 nm
Physical Sampling Interval: 3.5 nm
Optical Resolution: 10 nm
Spectral Reporting: 380-730 nm in 10 nm Steps
Measurement Frequency in Scanning Mode: 400 Measurements per SecondOpticsMeasurement Geometry: 45°/0° Ring Illumination Optics, ISO 13655:2017
Measurement Aperture: 0.31\" / 8 mm Diameter (Effective Measurement Aperture During Scanning is Depending on the Patch Size and Measurement Speed)
Illumination Spot Size: 0.47\" / 12 mm
Light Source: LED Illumination (Including UV)ReflectiveData Format: Spectral Reflectance [Dimensionless]

Measurement Conditions:
M0 - UV Included - ISO 13655:2017
M1 - D50 - ISO 13655:2017
M2 - UV Excluded - ISO 13655:2017
M3 - Polarization - UV Excluded - ISO 13655:2017
OBC: Optical Brightener Compensation (OBC) with i1Profiler Software
Calibration: Manual on External Ceramic White Reference
Measurement Background: White, ISO 13655:2017; for Measurements on Backup Board
Minimal Media Thickness: 0.12\" / 3 mm on Backup Board

Minimal Patch Size in Spot Mode
0.55 x 0.55\" / 14 x 14 mm

Minimal Patch Size in Scanning Mode
0.63 x 0.63\" / 16 x 16 mm with i1iO
0.63 x 0.63\" / 16 x 16 mm with Sensor Ruler
0.79 x 0.63\" / 20 x 16 mm without Sensor Ruler
0.79 x 0.63\" / 20 x 16 mm with Sensor Ruler in M3 Mode
0.87 x 0.63\" / 22 x 16 mm without Sensor Ruler in M3 Mode

Maximum Scan Length
20.28\" / 515 mm
Inter-Instrument Agreement: 0.4 Δ E00* average, 1.0 Δ E00* Maximum (Deviation from X-Rite Manufacturing Standard at a Temperature of 73.4°F / 23°C on 12 BCRA Tiles (D50, 2°)
Short-Term Repeatability: 0.1 Δ E00* on White (D50,2°, Mean of 10 Measurements every 3 Seconds on White) Spectral Radiance [mW/nm/m2/sr], Luminance [cd/m²]EmissionData Format: Spectral Radiance (mW/nm/m2 /sr); Luminance Y (cd/m²)
Measurement Range: 0.2-5000 cd/m² on a Typical LCD Monitor
Short-Term Repeatability: x,y: +/- 0.002 typical (5000K, 80 cd/m²)Ambient Light MeasurementData Format: Spectral Irradiance [mW/nm/m2], Illuminance [lux]
Type: Cosine-Corrected Diffuse Light Measurement HeadInterfaceUSB 1.1Power SupplyUSB Bus-PoweredOperating ConditionsTemperature: 50-95°F / 10-35°C
Humidity: 0-80% (Non-Condensing)Dimensions6.4 x 2.7 x 2.5\" / 162 x 69 x 64 mmWeighti1Pro 3 Device: 10 oz / 285 gPackaging InfoPackage Weight9.7 lbBox Dimensions (LxWxH)17.1 x 13.9 x 6.2\"