This is a ionization chamber and is often called a Geiger Counter.
This was found in a storage box in a school I was working at in 1980.
It is time to let it go to someone who collects these items or have it around for a conversation piece as I have.
It does generate lots of interest.It had batteries in it when I first had it and miraculously, they did not leak or damage any terminals or anything else in the unit. I don\'t know if one can still get batteries, but a imagine that they could be obtained by a specialist familiar with batteries,The tester is marked \"FCDA Item No. CD V-720 Mod 2\", \"Victoreen Model 720\", \"Mfgd. For the FCDA By The Victoreen Instr. Co.\", and \"Cleveland, Ohio USAThe below is what I know about these.The CD V-720 is a high range (0-500 R/h) ionization chamber that is also capable of responding to beta radiation. According to the Handbook for Radiological Monitors, it “is designed (1) for ground survey (2) for use in fallout monitoring stations and community shelters, and (3) as an interim aerial survey instrument. It will be used by the monitor for the major portion of survey requirements in the period immediately following a nuclear weapon attack.”
The CD V-720 employs the standard two controls for an ionization chamber: a range switch and a zero adjust. The sealed air-filled chamber has a thin window (located on the bottom of the case towards the front). The latter is protected and supported by a metal plate perforated with holes (ca. 0.5” diameter). For gamma measurements, the beta shield is positioned over the window. The shield is slid towards the back of the case when it is necessary for the instrument to respond to betas. Note that the instrument is only calibrated for gammas.
The oldest reference I have found for the CD V-720 is the 1958 reprint of the 1955 Technical Bulletin TB-11-20 Radiological Instruments for Civil Defense.
Here is the Bulletin\'s description of what the CD V-720 was intended to be: \"A high-range beta-gamma survey meter is required for use by highly qualified monitors if it becomes necessary to make measurements in areas where extremely high-level contamination exists and for making high level beta radiation measurements (see Figure 4). This instrument will have three scales, 0-5, 0-50 and 0-500 r/hr gamma and will have a discriminating slide to permit the measurement of gamma only or of gama [sic] and beta radiation. The range of beta sensitivity will be several thousand reps per hour. OCDM Standard Item Specification CD V-720.\"
Note that the reprinted Bulletin references the OCDM even though the latter didn\'t exist in 1955—this particular change was made at the time of reprinting. The photo above right was used to illustrate the CD V-720 in TB-11-20. The text on the meter indicates that it is an \"Experimental Model\" produced by the Victoreen Instrument Company for the Federal Civil Defense Administration.
The above scene showing the CD V-720 comes from the movie Radiological Defense (produced by the Office of Civil and Defense Mobilization in 1961).
Chatham Electronics Model 1
The earliest reference I have to a production version of the CD V-720 is the Chatham Electronics advertisement in the September 1956 issue of Nucleonics that reads: \"Model CH-720 Survey Meter. Beta-gamma discriminating ionization chamber survey meter. Three ranges... 0-5, 0-50, 0-500 r/hr full scale. Sliding shield excludes beta. Complies with F.C.D.A. specifications CD V-720 for high range Civil Defense survey meters.\" The model number uses a CH designation, but the photo shows an instrument very similar to the Model 1 with the CD logo on the side.
The example pictured above is a Chatham Electronics Model 1. The military version produced by Chatham was theIM-123/PD.
The case of the instrument shown below, a Victoreen Model 2, is solid plastic with the exception of the metal sliding beta shield on the bottom.
Victoreen Model 2
This has to be one of the worst designed ion chambers of all time. The metal clips used to connect the upper and lower portions of the case are held in place with a cheesy plastic connection—just like the latch on the Victoreen CD V-710 Model 5. It is almost a miracle that some of these instruments have survived unbroken. What you typically encounter are repair jobs.
Even the handle is easily snapped off.
In the environment of a post-nuclear strike where the CD V-720 was intended to be used, finding the duct tape and glue to repair the thing might not be easy.
The following statement comes from a June 1959 revision of a 1955 Civil Defense Technical Bulletin: \"To provide a capability for meeting the various requirements of civil defense operations and training, OCDM has developed the following types of instruments:... \"A high-range survey meter to measure and discriminate between beta and gamma radiation in areas where high dose rates exist (CD V-720).\" The accompanying photo in the bulletin appears to be the Victoreen Model 2.
Since an OCDM Advisory Bulletin dated January 8, 1959 refers to the Model 2 but not the Model 3, the Model 2 must have been introduced prior to 1959, and it is likely that the Model 3 was first produced in 1959 or later.
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.