Global customer service and more:
whatsapp :+86 15021132129
Introduction
It is a medical Syringe Pump, features in high intelligence, high safety, simple operation and stable working; displaying real-time parameters accurately by an LCD; audible, visible and text alarm; high injection accuracy; detecting the syringe specification automatically. It was widely used in medical institutions for clinical nursing and various occasions for intravenous injection, such as ICU, CCU, neonatology, obstetrics and gynecology, pediatrics, internal medicine, surgery, operating room, emergency room, etc.
Function
1.Be compatible with multiple syringe brands. The injection accuracy can be guaranteed by calibrating.2.Identify the syringe specification automatically, with the alarm function of improper specification.3.Display real-time parameters (such as accumulated volume, remaining time) by the 2.8\" TFT LCD.4.Injection reminder function.5.The injection parameters can be saved after shutdown.6.Audible and visual alarm function.7.Audible and visual alarm function.8.With purge function, convenient for supplying temporary and rapid medication.9.Adjustable occlusion threshold (high, middle and low), be used for monitoring the real-time pressure.10.The parameters and syringe type settings are protected by the password, prevents random changes.11.Intelligent dual-way power supply (AC, built-in high capacity lithium battery).
Performance
1.Specification for syringe:10 ml / 20 ml / 30 ml / 50 ml syringe met national standards2.Injection rate:10 ml 0.1 ml/h~200 ml/h20 ml 0.1 ml/h~400 ml/h30 ml 0.1 ml/h~600 ml/h50 ml 0.1 ml/h~1200 ml/h3.Purge rate:10 ml 200 ml/h20 ml 400 ml/h30 ml 600 ml/h50 ml 1200 ml/h4.Accumulated volume:0.1 ml~9999.9 ml5.Injection accuracy:±3 %6.Pressure range of occlusion alarm:Low: 40 kPa (± 16 kPa)Middle: 70 kPa (± 30 kPa)High: 100 kPa (± 35 kPa)7.KVO rate:0.1 ml/h8.Class:Class II, type BF applied part, internally powered equipment9.Alarm:①Occlusion for syringe②Syringe falls off③Motor abnormal④Pressure failure⑤Enter KVO mode⑥Battery exhaustion⑦No syringe installed⑧Inject will over⑨Low battery⑩Standby prompt10.Maximal power consumption:25 VA, at least 4-hour continuous operation at the injection rate of 5 ml/h after fully charged11.Power supply:100 -240 V~, 50/60 Hz12.Battery:lithium battery:7.4 V,5000mAh
Accessories
Standard configurationSyringe pumpBracketPower cableQuantity1&1 &1
Physical characteristic
Dimension:305 mm (L) × 132 mm (W) × 114 mm (H)Weight: 1.7 Kg