Product Description:
Features:
- Data backup.you canbackup all theenrollments data intoa memory IC and then restore to othersame devices.
- Delete/Add cards by master card,
- Anti-probe the password
- AddID cards by the room number,such ascan namecards to the controller as\"201\"(201 is a room number),emember
the cardsbut not its real number so that you don\'t have to remember all thecards\' number especially when a card lost. 5.Capacity can be extended up to 16K if you need. 6. It has 3 modelsthose are compatible with Mifare1/Hid/EM ,please look the tablet below.
Parallel all the models support: open the door by password, by card + password , manage the device by master card,data backup
and restore by memory IC.
Extendable Optional:Remote control,RFID reader
Card Type:
Card use card
2
Daytime using card,invalid during evening
3
Password attached card,must typing in PW after card reading whenever
4
Password attached during evening.Only card reading is valid during daytime
Pin Description and wiring open of relays, capacity point of relays, capacity close of relays, capacity to open switch
7
DOOR
Connect to door magnetic sensor
8
ALM
Alarm bell output port, current load 100mA
9
WG0
Wiegand 26 reader data lines (data 0),when a reader 26 reader data lines (data 1) ,when a reader switch,
Operation In
0*password# .Default administrative password:1234
Log off
0*#
The functions below should be operated in a Log in status
Change password
1*newpassword# (password should be 4~6 bits)
Dispatch user PW
2*userpassword#(user password should be 4~6 bits)
Delete user PW
3*user password#
Delete all user PWs
3*9*9#
Dispatch type 1card
4*1# card reading(if more cards,can read card continuously)
Dispatch type 2 card
4*2# card reading(if more cards,can read card continuously)
Dispatch type 3 card
4*3# card reading(if more cards,can read card continuously)
Dispatch type 4 card
4*4# card reading(if more cards,can read card continuously)
Dispatch a remote
4*5# pressing any key of the remote,the device beep once means OK.
Delete cards
5*card number# (card number is a 10 bits printed on card)
Delete all cards
5*9*9# (the device beep once means finished)
Delete a card type
6*card type#
Delete all cards&PW
6*9*9#
Setup to night mode
7*password#
Setup to Normal Open
8*password#(conveniently for going to work every morning)
Setup open delay
9*seconds# (seconds is a 0~99 digit means the duration of delay)
Setup fault PW times
10*fault times#(a 2~9 digit,means fault PW entering times,default is 5)
Setup device suspend time
11*suspend time#(1~99 ,means 1~99 seconds,default is 10)
Restore the Manufacture setup
12*#
Setup stress PW
13*stress PW#(4~6 bit)
The functions below should be operated in a normal status
PW open
PW #
Card open
Card reading,(if a PW needed,press the PW)
On/Off the night mode
7*PW #
On/Off NO status
8*PW #
Modify the user PW
after card reading,press *1* new password# during green light flashing
Turn on the Stressing Alarm
Stress PW#
Turn off the Alarming
Read any authorized user card
Others
- press ** anywhen will exit
- if the operation is right,the buzzer will sounda long beep,if wrong operation,3 short beep.
- Press and hold the reset button for 1 second,one beep,all the setup will be restore to manufacture default.
- Press and hold the reset button for 3 seconds,not only restore the manufacture default,but also delete all the data including dispatched cards and PW