Keyence LV-N11P Amplifier, Cable, Main unit, PNP New in Box
This is a Keyence LV-N11P Amplifier, Cable, Main unit, PNP New in Box.
What you will get:
- Keyence LV-N11P Amplifier, Cable, Main unit, PNP New in Box
This is my item R2B8S6 N2762-N2767.6 were available at listing time.
Check out myother itemswhere I have a lot of otherscientific equipmentandaccessories for sale.
More Information:
Model LV-N11P
Type 2 output
Output PNP
Cable/connector Cable
Main/Expansion unit Main unit
I/O Control outputs 2 output
External input 1 input
Monitor output None
Output selection LIGHT-ON/DARK-ON (switch-selectable)
Timer function Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
Timer duration selectable: 1 ms to 9,999 ms,
Maximum error against the setting value: ±10% max.
Control outputs PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less
Response time 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 Monitor output - External input Input time 2 ms (ON)/20 ms (OFF) or more*2 Number of interference prevention units Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3
Case size H 32.6 mm 1.28\" × W 9.8 mm 0.39\" × L 78.7 mm 3.1\"
Unit expansion Up to 17 units can be connected in total (two-output type is treated as two units)
Protection circuit Reverse polarity protection, Over-current protection, Surge absorber Rating Power voltage 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5
Power consumption Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*6 Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*6 Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V) *7
Environmental resistance Ambient temperature -20 to +55 °C -4 to 131 °F (No freezing)*8
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm 0.06\", 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Material Cable PVC Case Main unit and cover material: Polycarbonate Weight Approx. 75 g
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when \"DOUBLE\" is selected.
*4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*5 To connect more than 9 units, the power voltage must be 20 V or more.
*6 Increases 30 mW (1 mA) for HIGH SPEED mode.
*7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
*8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.
Please use the shipping calculator to determine shipping.
If you receive your item and it is not to your 100 Percent Satisfaction, please contact us before leaving response.
I strive to make sure every transaction is a positive one!
IF you have a problem with my item, I would like you to use the \"Contact Seller\" link in the listing, or call me. Please don\'t open a case. Cases count against me even if they are resolved.
I stand behind my items and will work out any problems that you may have with an item.
So please contact me if you have a problem with an item I have sold you and don\'t use the Case as a means of communication.
International Buyers, Please Note: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer\'s responsibility. Please check with your country\'s customs office to determine what these additional costs will be prior to offerding/buying. These charges are normally collected by the delivering freight (shipping) company or when you pick the item up do not confuse them for additional shipping charges. We do not mark merchandise values below value or mark items as \"gifts\". US and International government regulations prohibit such behavior.
Powered by SixBit\'s eCommerce Solution