Keyence FS-M1P Fiberoptic Sensor Fiber Amplifier, PNP, Manual Calibration

Keyence FS-M1P Fiberoptic Sensor Fiber Amplifier, PNP, Manual Calibration
$101.70

Buy Now

unit

Output

PNP

Light source

Red LED

Sensitivity adjustment/Mode selection

8-turn trimmer (with indicator), FINE/TURBO (switch-selectable)

Response time

250 µs (FINE) /500 µs (TURBO)

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output: Red LEDStable operation: Green LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF output

PNP open-collector 100 mA max. (40 VDC max.), Residual voltage: 1 V max.

Stability output

PNP open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max.*1

Protection circuit

Reversed polarity protection, over-current protection, surge absorber

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units).*2

Mutual interference suppression

FINE : 4, TURBO/SUPER: 8

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

35 mA or less

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-10 to +55 °C14 to 131 °F(No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm0.06\", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case 75 g

*1Only the FS-T1 and FS-M1 can provide stability outputs.*2If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.3 to 10 Units: -10 to 50°C14 to 122°F, 11 to 16 Units: -10 to 45°C14 to 113°F*3When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.When 3 to 10 units: -10 to +50 °C14 to 122 °FWhen 11 to 16 units: -10 to +45 °C14 to 113 °FWhen connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.