Digital STC-1000 Temperature Controller Computer Constant Temperature

Digital STC-1000 Temperature Controller Computer Constant Temperature
$59.97

Buy Now





Technical Parameters:
1.Temperature measuring range: -50 ° C ~ 99 ° C
2.Resolution: 0.1 ° C;
3.Accuracy:±1° C (-50 ° C ~ 70 ° C);
4.Sensor error delay: 1 minute
5.Power supply: 12V , 24V,110-220V( Choose power supply when you place order ) ;
6.Power consumption: <3W;
7.Sensor: NTC sensor (1PC);
8.Relay contact capacity:
9.Ambient temperature: 0 ° C ~ 60 ° C;
10.Storage temperature: -30 ° C ~ 75 ° C;
11.Relative humidity: 20% ~ 85% (No condensate)
12.Sensor length: 1.0m(included the probe)
13. Front Panel Size: 75x34.5mm ; Product Size: 75x34.5x85 mm ; Mounting Size: 71x29mm
Key operation instruction
1 .The way to check parameter:
Under normal working status, press \"up\" key it displays temperature setting value; press \"down\" key it displays the difference value.
2. The way to set parameter:
Under controller normal working status, press \"s\" key for 3s or more to enter parameter modifying mode, and the \"Set\" indicator light on, screen displays the first menu code \"F1\".
Press \"up\" key or \"down\" key to adjust up and down and display the menu iem and the code of the menu item.Press \"s\" key to display the parameter value of the current menu. Press both \"s\" key and hold \"up\" key or \"down\" key simultaneously to choose and adjust the parameter value of the current menu value promptly. After finishing the setting, press and release the \"(I)\" key instantly to save the parameter modified value and return to display the normal temperature value. If no key operation within 10 seconds, system won\'t save modified parameter, screen back to display normal temperature.
3. Restore system data
When electrified, system will check itself, screen will display \"Er\" if error exit, please press any key at this time, and it restores default value and enter into normal working mode, it is advised to reset the parameter value under such conditions.

Operation instruction

Under controller normal working status, press and hold \"(I)\"key for 3s can turn off the controller; Under controller \"off\" status, press and hold \"(I)\" key for 1s can turn on the controller.
Under the controller normal working status, screen displays the current measuring temperature value; also the controller can also switch the working mode between heating and cooling.
Controller starts refrigerating with cool indicator light on when the measuring temperature value >= temperature set value + difference value, and the refrigerating relay is connected; If the “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature values temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
System starts heating when the measuring temperature value <= the temperature set value-difference value, and the \"Heat\" indicator light on, the heat relay connects; When the measuring temperature >= temperature set value, the \"Heat\" indicator light is off, and the heat relay disconnects.
Error/Alarm description
Alarm when sensor error: Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all therunning status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound,system back to display the normal temperature when the error and the fault is cleared.
Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm functionwhen the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzeralarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal working mode when the temperature restore to normal measuring range.


Safety Regulations
Danger:
1.Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong
connections or overloading the relay.
2.Dangers: Prohibit connecting the wire terminals without electricity cut-off.
Warning:
Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or
strong corrosion.
Notice:
1.The power supply should conform to the voltage value indicated in the instruction.
2.To avoid the interference, the sensor down-lead and power wire should be kept a distance.


Thanks. 1.We only ship to your confirmed address. Please make sure your shipping address is correct before purchase.Please your telephone no,as the shipping company may need at the time of deliver.
2.All the orders will be shipped out within 1 - 5 business days upon payment confirmation.
3.The shipment by SpeedPAK Standard generally it will take 7-15 working days(some countries can be much longer), if you need the goods very urgently, please contact us for DHL or Fedex etc. We will calculate the shipping cost for you .It always takes about 3-7 working days to arrive.
4.We ship worldwide by EMS,DHL,UPS,FedEx,TNT,China post,E-packet,Singapore Post,Hong Kong Post and so on.We are unable to control the delivery time because it is by Third-party service,but if the parcel has not arrive within expected time,please contact us,we will help you to track it and give you a satisfied reply.
Always contact us if you have any with your purchase or the item, we are always there to help you. Don\'t open case or leave negative response without contacting us

1.100% Money Back Guarantee...Shop With Confidence. buyer should pay return cost.

2. We abode by Distance Selling Regulations 2000 and always try to resolve the and are committed to resolve issues based on rules and our sale policy.The must be returned within 30 days.
For quality ,please contact us and us with evidence.As the items returned, Buyer should pay for the return shipping fee.

A l l duties, taxes in the buyer\'s country are taken care by buyer only. Butwewilltrybestdeclaretheitemin real and
Any type of custom duties will be payed by buyer. Please note refund will be payed when the will reach to us.

Please do not leave Negative response.if you have any with the item,have any question ,or simply need help please contact us for a resolution.Our Team\'s goal is to earn 5 star rating with every purchase !!Please contact us with any questions or concerns or through Messaging System before leaving a natural or negative response.(Thank You)

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design