Product Description Specifications Part Number RS-485 output
FLR-10-RS485-M
FLR-50-RS485-M
FLR-100-RS485-M
Part Number 4...20mA
FLR-10-AA-M
FLR-50-AA-M
FLR-100-AA-M
Measuring range
30...100mm
80...500mm
150...1000mm
Full range(F.S.)
70mm
420mm
850mm
Supply voltage
RS-485:10. ..30VDG; 4.. .20mA: 12...24VDC
Consumption power
≦700mW
Load current
200mA
Voltage drop
<2.5V
Light source type
Red laser(650nm);Laser level:Class 2
Light spot size
Φ1mm@3mm@100mm
Φ2.5mm@500mm
Φ3mm@1000mm
Dimension
65*51*23mm
Resolution
5um@30mm; 50um@100mm
15um@80mm; 500um@500mm
50um@150mm; 2000um@1000nim
Linear accuracy①②
Please refer to the specification of specific models
Repeated stabilily①②③
10um@30mm 30um@50mm 100um@100mm
30um@80mm 250um@250mm 1000um@500mm
100um@150mm 520um@500mm 4000um@1000mm
Output 1
Digital value:RS-4S5(Support ModBus protocol);Analog:4...20mA(Load resistance
Output 2
Switch value:PUSH-PULL/NPN/PNP NO/NC Settable
Distance setting
RS-485:keypress/RS-485 setting;4... 20mA:keypress setting
Temperature drift
±0.02%F.S./°C
Response time
2ms,16ms, 40ms Settable
Indicator Power indicator:Green LEDjMotion indicator:Yellow LED;Alarm indicator:Yellow LED
Display
OLED Display(Size: 14*10.7mm)
Built-in function④
•Slave address&Port rate setting •Zero set •Product self-check •Output setting •Parameter query •Average setting •Analog map
settings •Single point teach •window teach •Factory default
Protection circuit⑤
Short circuit, reverse polarit^overload protection
Service environment
Operating temperature:-10.. .+50°C; Storage temperature :-20.. .+70°C Environment humidity:35...85%RH (No condensation)
Anti ambient light
Incandescent Iight:
Protection degree
IP67
Material
Housing:Aluminium;Lens cover:PMMA Display panel: PC
Vibration resistant
10...55Hz Double amplitude lmm,2hrs each for X/Z direction
Impulse withsand
500m/s2(About 50G),3 times each for X,Y,Z direction
Connection way
2m 5pin/4pin PVC cable (5pin: RS-485 output;4pin:Analog output)
Accessoiy
Screw(M4X 35mm) X2^ NutX2、WasherX2^ Mounting bracket、Operation manual
Remark: ①Test conditions:Staiidard data at 23 ± 5 °C;Supply voltage 24VDC;30 minutes\' warmup before test; Sampling period 2ms;Average sampling times 100; Standard sensing object 90% white card
②The statistical data follows the 3
③Repeat accuracy:23 ± 5 °C environment^。% reflectivity white card, 100 test data results
④Slave address,baud rate setting only for RS-485 series
⑤ Protecion circuit only for switch output
Product Dimensions
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.