BAPI BA/10K-2-H210-D-BB 10K-2 Thermistor Humidity Transmitter Duct
$182.77

Product Description The Bapi BA/10K-2-H210-D-BB is a duct-mounted humidity transmitter that uses a 10K Type 2 thermistor and provides field-selectable 4-20 mA or 0-5/0-10 VDC outputs. It operates on 15-28 VAC/VDC, measures 0-100% RH with +/-2% accuracy (20% to 95% RH), and is housed in a NEMA 4 / IP66 BAPI-Box with a replaceable 80 micron stainless steel sintered filter and medical-grade foam probe seal. Typical applications include HVAC duct monitoring, economizers, clean rooms, and data centers. - Sensor: 10K Type 2 thermistor; sensing technology resistive with ceramic substrate; +/-2% RH accuracy (20% to 95% RH)
- Field-selectable signal outputs: 4-20 mA (700 ohm) or 0-5/0-10 VDC (10 kohm minimum); supply 15-28 VAC/VDC
- Duct BAPI-Box enclosure rated NEMA 4 / IP66 with replaceable 80 micron stainless steel sintered filter and medical-grade closed cell foam probe seal
Product Highlights 10K Type 2 thermistor; +/-2% RH accuracy; field-selectable 4-20 mA / 0-5/0-10 VDC; 15-28 VAC/VDC; NEMA 4 / IP66 duct housing Product Information Standard Information - Brand: BAPI
- Manufacturer Part Number: BA/10K-2-H210-D-BB
Technical Specifications - Brand: BAPI
- Manufacturer Part Number: BA/10K-2-H210-D-BB
- Alternate Part Number: BA-10K-2-H210-D-BB
- Sensor Element: 10K Type 2 thermistor
- Sensing Technology: Resistive with ceramic substrate
- Accuracy: +/-2% RH (20% to 95% RH)
- Humidity Range: 0% to 100% RH
- Output: Field-selectable: 4-20 mA (700 ohm); 0-5 VDC or 0-10 VDC (10 kohm minimum)
- Input Voltage: 15-28 VAC/VDC
- Enclosure Rating: NEMA 4 / IP66 (duct/OSA, BAPI-Box)
- Enclosure Material: Poly (BAPI-Box; UV-resistant polycarbonate per additional sources)
- Enclosure Dimensions: 5 x 4.1 x 2.5 inches
- Mounting Type: Duct
- Sensor Protection: 80 micron stainless steel sintered filter; medical-grade closed cell foam probe seal
- Operating Humidity: 0-100% non-condensing
- Operating Temperature: -40 to 158 F (-40 to 70 C)
- Wiring Terminations: Four-wire, 16 to 22 AWG terminals
- Weight: 1.0 lb (0.45 kg) (OSA/Duct)
- Approvals: CE, RoHS
- Accessories: DCPA-1.2, DCP-1.5-W, T81U-XR, T85U-XR, UR