Aeroflex/IFR 2399A 9 kHz-3 GHz Spectrum Analyzer
Comes with what you see in the pictures. If you don\'t see it, you probably won\'t get it.
Specifications are from IFR/Aeroflex and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
This unit ships fully tested and guaranteed to work for 30-days, parts and labor, excluding freight.
The Unit\'s Serial Number Tag Reads:
Model Number: 2399A
Serial Number: I04092071
CE Marked: Yes
Options Installed:
05: Tracking Generator
10: Internal Amp
11: GPIB Interface
Version Information:
System Version: 4.20 - 08-12-2004
API Version: 4.20 - 08-12-2004
DSP Version: 1.62 - 02-05-2003
FPGA Version:
XCS30_DSP: 0.4 - 11-25-2002
XCS30_ISA: 0.6 - 11-25-2002
XC9536_CPU: 0.3 - ID: 101
catv9536: 31.31 - ID: 1023
Features:
9 kHz to 3 GHz fully synthesized frequency range
Lightweight, portable and rugged construction at 9.4 kg
Excellent TFT color display
Comprehensive marker facility
Wide input signal range - +30 dBm to -110 dBm
Optional full range tracking generator
Semi-automated measurements
Low floor noise
Floppy disk drive
Extremely user friendly MMI reduces risk of operator error
Auto-Tune facility
GPIB as standard
AM/FM demodulationFrequency Specifications:
Tuning Range: 9 kHz to 3 GHz
Resolution: 1 Hz
Frequency Span Width: 100 Hz/div to 300 MHz/div in 1, 2, 5 step selections (auto-selected). Zero span and Full span (9 kHz to 3 GHz). Manual selection of Start, Stop and Span
Span Accuracy: ±3% of indicated span width
Readout Accuracy: ±(span accuracy + frequency standard accuracy + 50% of RBW)
Stability: Residual FM < 100 Hz p-p at 1 kHz RBW, 1 kHz VBW, (p-p in 20 ms)
Noise Sidebands: -90 dBc/Hz at 10 kHz offset measured at 2.9 GHz. -98 dBc/Hz at 100 kHz offset measured at 2.9 GHz.
Frequency Counter Specifications:
Resolution: 1 Hz, 10 Hz, 100 Hz, 1 kHz
Accuracy: ±(Reference frequency error + frequency readout accuracy + counter resolution ±1 count)
Sensitivity: < -70 dBm from 50 kHz to 3 GHz
Amplitude Specifications:
Measurement Range: +30 dBm to -110 dBm
DANL: 50 kHz to 100 kHz ≤ -95 dBm amp out, Amp Out (Typ.) -105 dBm, Amp In (Typ.) -117 dBm. 100 kHz to 3 GHz ≤ -105 dBm amp out, -115 dBm Amp Out (Typ.), -127 dBm Amp In (Typ.). 300 Hz RBW, 10 Hz VWB
1 dB Compression Point: -10 dBm minimum 100 kHz to 3 GHz at 0 dB attenuation
Displayed Range: 100 dB in 10 dB/div log scale, 50 dB in 5 dB/div log scale, 20 dB in 2 dB/div log scale, 10 dB in 1 dB/div log scale, 10 divisions with linear amplitude scale.
Amplitude Units: Log scale modem dBm and dBmV. Linear scale mode V (µV, mV, etc.) or dBV (dBmV only). Quasi-Peak mode dBµV, dBmV or dBm
Display Linearity: 5 and 10 dB/div, ±0.15 dB/dB, ≤ ±1.5 dB over 10 divisions. 1 and 2 dB/div, ±0.5 dB over 10 divisions. Linear, ±10% of Reference Level over 10 divisions
Frequency Response: ±1.5 dB from 10 MHz to 3 GHz and ±2 dB from 9 kHz to 10 MHz with 10 dB RF attenuation.
Attenuator Specifications:
Range: 0 dB to 50 dB in 10 dB steps selected manually or automatically coupled to the Reference Level
Accuracy: ±0.5 dB/step up to a 1.5 dB maximum
Reference Level Specifications:
Range: -110 dBm to +30 dBm with 1 kHz filter using 1 dB/div scale
Accuracy: ±1.5 dB (50 kHz to 3 GHz)
Resolution: 0.1 dB steps
Residual Spurious: ≤ -85 dBm (input terminated, 0 dB attenuation)
Harmonic Distortion: ≤ -60 dBc (-40 dBm input at 0 dB attenuation)
Intermodulation: ≤ -60 dBc (100 MHz to 2.9 GHz at -30 dBm input)
Other Spurious: ≤ -60 dBc (10 MHz to 2.9 GHz at -30 dBm)
Resolution Bandwidth Specifications:
Selection: 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz, 300 kHz, 1 MHz, 3 MHz + 10 Hz, 30 Hz, 100 Hz (option 5)
Accuracy: ±20%
Selectivity: 60 dB/3 dB ratio < 15:1 except 3 MHz filter 50 dB/3 dB ratio < 15:1. 60 dB/6 dB ratio < 12:1 for 9 kHz and 120 kHz Quasi-Peak filters
Switching Error: ±1.0 dB
Video Selection: 10 Hz to 1 MHz in 1-3-10 sequence plus full BW
Sweep Specifications:
Rate (full screen): 50 ms to 1000 s in 1-2-5 sequence, 25 µs to 20 s in Zero Span
Sweep Rate Accuracy: 20% for < 100 ms, 10% for all other sweep rates
Trigger Source: External, Line, Video, Free Run
Trigger Modes: Continuous, Single
Trigger Level:
Internal Trigger: Adjustable over 10 divisions
External Trigger (Rear): TTL Level
Trigger Delay: ±One sweep time
Display Specifications:
Type: 6.4 in. TFT color LCD
Digital Resolution: 640 H x 480 V active display area
Markers Specifications:
Number: Up to 9 colored Markers available with 9 Delta Markers
Modes: Normal, Delta, Peak Search, Peak Track, 1/Delta, Marker Track, Marker to Center, Marker to Reference. All Markers to peak
Marker: Marker to track, Marker to center, Marker to reference, Marker to peak
Memory Specifications:
Trace Storage: Up to 1,000 stored traces stored internally
Setup Storage: Up to 2,000 operational states stored internally
External: 3.5 in. FDD for bulk storage
Displayed Traces: 2
Inputs Specifications:
RF Input: Type \"N\" 50 Ohm female connector
Input VSWR: < 1.5:1 from 150 kHz to 3 GHz with 10 dB attenuation
Maximum Input: +30 dBm with 30 dB attenuation, 50 Vdc
LO Emissions: ≤ -70 dBm with 10 dB attenuation
Outputs Specifications:
IF Output: 10.7 MHz nominal
Video Output: 0 to 5 Vdc, VGA output
Printer Drivers: PCL5 compatible via standard 25-pin female D-Sub Parallel Printer
Probe Power: +15 V, -12 V and Ground
Interfaces Specifications:
GPIB: Conforms to IEEE 488.1 - 1987, 488.2 - 1992
Subsets: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, C0, LE0, TE0
RS-232C: Full Duplex
Baud Rate: 110 bps, 300 bps, 600 bps, 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19.2 kbps, 38.4 kbps, 57.6 kbps, 115.2 kbps
Parity Check: Odd, Even or None
Data Length: 7 or 8 bit selectable
Stop Bits: 1 or 2 bit
Protocol: None, Xon-Xoff, RTS-CTS, DTR-DSR
Environmental Specifications:
Operating: 0 to 40°C
Storage: -20 to +70°C
Temperature & Humidity: Meets MIL-T-28800E for Type 2, Class 5, non-condensing (85% operating, 90% storage)
Vibration/Shock: Meets MIL-T-28800E for Type 2, Class 5
Altitude: Operational up to 3,000 m (19,842 ft.), non-operation to 12,200 m (40,026 ft.)
Product Safety Specifications:
Safety Conformity: Conforms to EN61010-1 for Class 1 portable equipment and is for use in a pollution degree 2 environment. The instrument is designed to operate from an installation Category II.
Electromagnetic Compatibility Specifications:
Compliance: Complies with the limits specified in the following standards: EN 55011: Class A and EN 50082-1
General Specifications:
Dimensions: 350 mm W x 185 mm H x 381 mm D (13.78\" x 7.28\" x 15\") - including handle
Weight: 9.4 kg (20.7 lbs.)
Warm-up Time: 15 minutes for specified accuracy
Power Requirements: 100 to 240 VAC ±10%, 50 to 60 Hz, 90 W max. w/o options fitted.
Tracking Generator Option Specifications:
Frequency Range: 100 kHz to 3 GHz
Output Level: 0 to -70 dBm
Output Level Resolution: 0.1 dB step
Absolute Level Accuracy: ≤ ±1.0 dB at 0 dB
Frequency Flatness: ≤ 2.0 dB at -10 dBm
Signal Purity:
Harmonics: ≤ -15 dBc
Non-harmonics: ≤ -25 dBc
Sub-harmonics: ≤ -25 dBc
Leakage: ≤ -90 dBm
For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $50.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.
Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
(1) Are you the end-user of this item?
(2) If you are not the ultimate end-user of the item, please state the ultimate end user\'s name.
(3) What is the ultimate country destination?
03/07/20
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.