>> If you dont know how to design a userbar, then write here a Userbar that you want.
>> If you know how to design them help these people and design what they request.
|
 |
 |
USERBARS.org | Free Forum Userbars
| On eBay now |
4CFM AC Vacuum Pump Kit w/ HVAC Manifold Gauge Set Leak Detector for R134a R410a
$109.99

4 CFM HVAC Vacuum Pump & Manifold Gauge Set – Complete AC Service Kit for Automotive and Home HVAC use.This 110V single-stage rotary vane pump delivers fast, deep evacuation down to 150 microns to remove moisture and air before refrigerant charging. Ideal for car A/C systems, residential HVAC maintenance, and refrigeration service.The manifold gauge set provides ±1.6% accuracy for reliable pressure readings. Includes three 5 ft color-coded hoses for secure connections.Compatible with R134a, R410a, R12, R22, and R502 (adapters included).Built-in cooling fan supports stable operation. Oil sight glass allows easy monitoring.Complete kit includes vacuum pump, manifold gauge, hoses, adapters, leak detector, vacuum oil, and carry bag — ready to use.4 CFM AC Vacuum Pump & Manifold Gauge Set Kit This 4 CFM AC vacuum pump and manifold gauge set is designed for automotive A/C recharge, residential HVAC maintenance, refrigeration service, and heat pump repair. The complete AC service kit includes a single-stage vacuum pump, manifold gauge set, leak detector, color-coded hoses, adapters, and essential accessories for refrigerant evacuation and charging. Features - 4 CFM Single-Stage Vacuum Pump – Delivers fast evacuation for automotive and HVAC systems. Removes moisture and air before refrigerant charging. Die-cast aluminum housing with anti-slip base for durability.
- Built-In Cooling Fan & Oil Sight Glass – High-volume cooling fan supports extended operation. Clear oil sight glass allows quick oil level checks. Bottom drain port simplifies oil changes. Includes 0.35 qt / 330 ml vacuum pump oil.
- Professional Manifold Gauge Set – Provides accurate pressure readings for refrigerant charging, evacuation, and diagnostics. Large viewing glass allows clear refrigerant flow monitoring. Shock-resistant core maintains accuracy during transport or daily use
- Color-Coded Reinforced Hoses – Includes three 5 ft reinforced hoses for high, low, and service connections. Compatible with R134a, R12, R22, R502, and R410a systems using included adapters.
- Complete HVAC Service Kit – Includes vacuum pump, manifold gauge set, leak detector, hoses, R410a adapters, R134a can taps, quick couplers, pump oil, and carry bag.
- IDEAL FOR DIY & PRO USE – Lightweight, portable pump with ergonomic handle, perfect for fast vacuum and refrigerant service on automotive A/C, residential HVAC, and heat pump systems, as well as 1–3 HP split, window, and portable AC units
Applications - Automotive A/C Recharge & Repair
- HVAC Vacuum Pump Operation
- Refrigeration Maintenance
- Leak Detection & Diagnostics
- Home & Commercial AC Service
Technical Specifications - Power: 1/3 HP (250W)
- Flow Rate: 4 CFM (114 L/min)
- Ultimate Vacuum: 5pa
- Motor Speed: 1440 RPM
- Voltage: 110V / 60Hz
- Port Size: 1/4" SAE & 1/2" ACME
- Pump Oil Included: 0.35 qt / 330 ml
Package Includes - 1 × 4 CFM Single-Stage Vacuum Pump
- 1 × Manifold Gauge Set (±1.6% accuracy)
- 3 × 5 ft Color-Coded Hoses
- 1 × Leak Detector
- 1 × Vacuum Pump Oil (0.35 qt / 330 ml)
- 2 × R410a Adapters (1/4" male to 5/16" female)
- 1 × Adapter (1/4" male to 1/2" female)
- 1 × R134a Self-Sealing Can Tap
- 1 × R134a Puncture Can Tap
- 2 × R134a Quick Couplers
- 1 × Top Pins
- 3 × Sealing Gaskets
- 1 × Portable Carry Bag
- 1 × User Manual
Quick Troubleshooting Pump won’t start or runs unevenly: - 1. Use stable power and check plug, wiring, capacitor, and switch.
- 2. Keep air intake open and connectors tight.
- 3. Operate between 5–40°C; if rotor is rusted, rotate counterclockwise. High temps may need multiple startups.
Pump does not reach expected vacuum: - 1. Replace dirty oil and keep it near the middle of the sight glass.
- 2. Check all hoses and interfaces for leaks and ensure sealing rings are intact.
- 3. Clean the exhaust valve if needed.
Oil leaking or spraying: - 1. Adjust oil level to avoid overfilling and keep the pump level while operating.
- 2. Reattach and clean the oil mist filter.
- 3. Ensure sealing rings and bottom valve are properly installed and tightened.
Gauge inaccurate or hoses leaking: - 1. Inspect hoses for damage or leaks.
- 2. Tighten connectors or replace sealing rings.
- 3. Adjust or replace the gauge head if readings are inaccurate and check interface fittings.
Leak detector issues: - 1. Ensure all four batteries are properly installed; replace old batteries if needed.
- 2. Test in a ventilated area using low and high sensitivity.
- 3. Confirm leaks with multiple methods: listen, smell, or use soapy water.