You may be interested Ambulatory Blood Pressure Monitor NIBP Holter Recorder with PC Software
$149
Ambulatory Blood Pressure Monitor NIBP Holter Recorder with 3 Size Cuff software
$159
3-channel 12-lead 5-inch color screen ECG Machine with PC Software
$400
Tips: The standard version of the product does not include the software function for connecting to a computer. If you need PC software, please purchase the option that includes this function.
Main Content Summary
1. Operation & Safety Notice
Read this manual carefully before use. Unauthorized modification or copying is prohibited.
Safety Icons (Danger, Warning, Attention, Notice).
This device complies with IEC60601-1, Type CF, Class I, and is defibrillator-protected.
Do not use in flammable gas environments or during MRI examinations.
Original accessories must be used. Non-professionals are prohibited from disassembling the device.
2. Device Overview
This device records ECG signals and features automatic analysis, high-resolution printing, and 12-lead simultaneous acquisition.
Powered by AC power and a built-in lithium battery.
Note: A normal ECG does not necessarily mean there is no heart disease; other tests should be performed in conjunction with the device.
3. General Information
This device includes the LCD screen, keypad, recorder, patient cable connector, and power connector.
LCD Display: Patient ID, gender, age, heart rate, battery capacity, system time, operating mode, etc.
4. Operation Preparation
Connect the power supply (three-core power cord, must be grounded).
Install the recording paper (80mm thermal paper).
Connect the patient cable (placement and color coding of limb and chest leads).
Check the environment, power supply, grounding, electrode connections, etc. before powering on the device.
5. Operation Instructions
Four operating modes:
Manual Mode
Auto 3s Mode
1-channel 1-minute Mode
Rhythm Analysis Mode
Menu settings: Filtering, waveform speed/gain, lead order, system settings, etc.
6. Daily Maintenance
Battery charging and replacement (recommended every three months).
Notes on recording paper usage and storage.
Equipment cleaning, patient cable inspection, thermal print head maintenance, fuse replacement, etc.
7. Troubleshooting
Common Problems:
No waveforms on certain leads
Printed waveforms are broken
Control panel malfunctions
AC interference, myoelectric interference, baseline drift, etc.
Provides inspection steps and solutions.
8. Technical Specifications
Input impedance ≥50MΩ
Common mode rejection ratio >100dB
Frequency response 0.05Hz~150Hz
Power supply: AC 100~240V, DC 14.8V lithium battery
Operating temperature: +5°C~+40°C
9. Appendices
Appendix A: Minnesota Code ECG Classification System.
Appendix B: Diagnostic Code Table (e.g., sinus rhythm, atrial hypertrophy, myocardial infarction, etc.).
ECG601
Packing:
- Single package size: 32*25*17cm
- Single gross weight: 2.8 KG
- 8 units per carton, package size: 54*33*75cm, total gross weight: 22 KG
Technical Specifications
Items
Specification
Lead
Standard 12 leads
Acquisition Mode
Simultaneous 12 leads acquisition
Measurement Range
±5mVpp
Input Circuit
Floating; Protection circuit against Defibrillator effect
Input Impedance
≥50MΩ
Input Circuit Current
<0.05μA
Record Mode
Automatic: 3CH×4+1R, 3CH×4, 3CH×2+2CH×3, 3CH×2+2CH×3+1R, 6CH×2; Manual: 3CH, 2CH, 3CH+1R, 2CH+1R; Rhythm: Any lead selectable.
Filter
EMG Filter: 25 Hz / 30 Hz / 40Hz / 75 Hz / 100 Hz / 150Hz
DFT Filter: 0.05 Hz / 0.15 Hz
AC Filter: 50 Hz / 60Hz
CMRR
>100dB
Patient Leak Current
<10μA (220V-240V)
Frequency Response
0.05Hz~150Hz (-3dB)
Sensitivity
2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV (error: ±5%)
Anti-baseline Drift
Automatic
Time Constant
≥3.2s
Noise Level
<15μVp-p
Paper Speed
12.5 mm/s, 25 mm/s, 50 mm/s
Recording Mode
Thermal printing system
Paper Specification
Roll 110mm x 20M
Safety Standard
IEC I/CF
Sample Rate
Normal: 1000sps/channel
Power Supply
AC: 100~240V, 50/60Hz, 30VA~100VA; DC: 14.8V/2200mAh, built-in lithium battery
Features:
- 7-inch high-resolution color touch screen
- 12-lead simultaneous acquisition and display
- ECG automatic measurement and interpretation function
- Complete digital filters, resisting baseline drift, AC, and EMG interference
- Compact and lightweight design
- Supports USB flash drive and micro SD card for extended memory
- Software upgrade via USB/SD card
- Built-in rechargeable Li-ion battery
Standard Configuration:
- Main machine: 1 PC
- Patient cable: 1 PC
- Limb electrode: 1 set (4 pcs)
- Chest electrode: 1 set (6 pcs)
- Power cable: 1 PC
- 110mm x 20M recording paper: 1 PC
- Paper axis: 1 PC
ECG1201
7-inch high-resolution color touch screen Full alphanumeric keyboard with shortcut keysfor efficient operation Simultaneous 12-lead ECG acquisition and display Automatic ECG measurements and interpretation Internal storage for up to 1000 cases, enabling convenient case review and statistics Built-in rechargeable high-capacity lithium battery ECG data transmission to PC via USB; reports can be saved, opened, and analyzed using ECG playback softwareStandard Configuration:
- Main machine: 1 PC
- Patient cable: 1 PC
- Limb electrodes: 1 set (4 pcs)
- Chest electrodes: 1 set (6 pcs)
- Power cable: 1 PC
- 210mm × 30M recording paper: 1 PC
- Paper axis: 1 PC
- Power cord: 1 PC
Packing Details:
- Single package size: 43 × 20 × 42 cm
- Single gross weight: 5.5 KG
- 4 units per carton, package size: 82.5 × 44.5 × 45 cm,total gross weight: 24 KG
Technical Specifications
Parameter
Specification
Lead
Standard 12 leads
Acquisition Mode
Simultaneous 12-lead acquisition
Sampling Rate
1000Hz
A/D Converter
24-bit
Frequency Response
0.05Hz – 160Hz (-3dB)
Operation Modes
Manual, Auto, Rhythm, 1-channel (1-minute recording)
Filters
AC Filter: 50Hz / 60Hz
EMG Filter: 25Hz / 35Hz / 45Hz / 75Hz / 100Hz / 150Hz
DFT Filter: 0.05Hz / 0.5Hz
CMRR
≥100dB (with AC filter)
Input Mode
Floating input with defibrillation protection
Input Impedance
≥50MΩ (at 10Hz)
Input Current
≤0.05µA
Input Dynamic Range
±10mVp-p
Patient Leakage Current
<10µA
Calibration Voltage
1mV ± 2%
Polarizing Voltage
≥300mV
Time Constant
≥3.2s
Paper Specification
210mm (width) × 30m (length)
Recording Mode
Thermal printing system
Noise Level
<15µVp-p
Internal Memory
1000 cases
Threshold
≤20µV
2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV (standard: 10mm/mV)
Paper Speed
12.5mm/s, 25mm/s, 50mm/s (accuracy ≥3%)
Power Supply (AC)
100–240V, 50/60Hz
Power Supply (DC)
14.4V, 2500mAh, 36.00Wh (built-in lithium battery)
Key Highlights:
✔Largethermal printing paper (210mm width)for detailed ECG traces
✔24-bithigh-resolution A/D conversionfor precise signal acquisition
✔Multi-mode operation(Manual/Auto/Rhythm)for flexible clinical use
✔Enhanced filteringoptionsto reduce interference (AC/EMG/DFT)
✔Long battery lifewithhigh-capacity Li-ion battery
Note: Specifications subject tochange without prior notice. For detailed operational guidelines, refer to theuser manual.
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.